Analysis Approach

The analysis is mainly done by taking out one reference case after a series of single point evaluations. As there was a striving towards a high solar fraction the reference case with the actual auxiliary fuel cost is not the minimum average annual cost which is depicted in Figure 7.

The reference case is:

collector area

20,000m2

collector cost

247US$/m2

storage volume

100,000m3

storage cost

27US$/m3

auxiliary fuel cost

0.05US$/KWh

weather

Boston

which

had results:

total annual cost

1.45M$

solar fraction

97.1%

Usi

ng

the MINSUN graphing function

sensitivity analyses

the

reference case by varying the

following parameters:

collector area

5-35,000m2

collector cost

175US$/m2

storage volume 20-140,000m3

storage cost

20US$/m3

auxiliary fuel cost

0.1US$/KWh

weather

Madison, Copenhagen

The

results

are displayed in terms

of:

total annual cost

solar fraction

Updated: August 24, 2015 — 12:59 am