TITLE: SODERTUNA ALTERNATIVECMULTIPLE WELL SYSTEM PERIOD: 1982

MAIN SUBJECTS OF RESEARCH:

– storage material: YES/ftf$

– storage system : YES/fNffl

– total system : YES/fNtS

1. Material :

2. Density :

granite

2700

kg/m3

3. Specific heat :

800

J/kg К

4. Mean heat capacity

2.1

MJ/m3 к {

5. Thermal conductivity :

3 – 3.5

W/m К

6. Permeability :

2

m

7. Operating temperature interval:

10 – 70

"C

8. Price :

100 SEK

UA/m3

Properties at temperature :

20

eC

1051000

COST (incl – cost for labour)

DATA OF TOTAL SYSTEM

The number of heat consumers in the entire system: 525 dwellings 1. Heat consumption system: space heftting/domestic hot water/both

space heat load*

: 30 10

MJ

hot water load*

: 20 103

MJ

total load*

: 50 103

MJ

total systaai load*

3

* 45 10

MJ

temperature increases towards centre of store

Figure 53: Sodertuna alt. С/Multiple well store – Schematic drawing

ies at temperature

The number of heat consumers in the entire system: 1 family residence 259 m2

[2] Heat consumption system: space heating/domeStic hot water/both

Solvarmecentral Lambohov Allmogegatan 66

[4] – 583 30 LINKOPING

The number of heat consumers in the entire system: 525 dwellings + 3500 m2 communal

areas

[6] Heat consumption system: space heating/domeStic hot water/both

Fuel: Fuel price

[8] Primary energy consumption for conventional system

2. Idem for solar heating system with seasonal heat storage

Frimary energy saved

Resume:

Primary energy saved:

Extra system cost : UA

REFERENCES: /25, 26/ CONTACT: P.0. KARLSSON

———- ————————————— Swedish State Power Board

[10] – 162 87 VALLINGBY Etoc

——— Hagkonsult AG

Box 1214

[12] – 181 23 LIDINGO

The number of heat consumers in the entire system:

[14] Heat consumption system: space heating/domestic hot water/both

space heat load* hot water load* total load* total systsm lead*

Fuel: Fuel price: $ 0.05/kWh

[16] Primary energy consumption for conventional system :

[17] Idem for solar heating system with seasonal heat storage: ____________

Primary energy saved : 3 GWh

Resume:

Primary energy saved: 3 GWh $ 150’000 CON 1983 annual saving

Extra system cost : $ 3501000 UA

Fuel: Fuel price)

[19] Primary energy consumption for conventional system

[20] Idem for solar heating system with seasonal heat storage;

Primary energy saved :

Resume:

Primary energy saved: Extra system cost :

The number of heat consumers in the entire system: simulated load

[22] at consumption system: space heating/domestic hot water/both space neat load* : MJ

hot water load* : MJ

total load* : MJ

‘280.10

M. HARDY

Joint Research Center Ispra Establishment

[24] – 21020 ISPRA

Updated: August 24, 2015 — 5:08 am